Thermal Accumulation in Low-Conductivity Polymers

Heat Accumulation Zones by Wavelength

Thermal Conductivity Impact on Marking

Polymers have thermal conductivities 100-1000x lower than metals, creating unique challenges:

Material Thermal Conductivity (W/m·K) Heat Dissipation Marking Behavior
Aluminum (reference) 237 Rapid Clean marking possible
PEEK 0.25 Very slow Heat accumulation issues
PLA 0.13 Extremely slow Severe thermal damage

Critical Physics Relationship

When optical penetration depth exceeds the thermal damage threshold depth, foaming becomes inevitable. The relationship is:

Foaming Risk = δ / (k × τ)
Where δ = penetration depth, k = thermal conductivity, τ = pulse duration

High risk values indicate the need for physics optimization to achieve clean marking.